お客様のプロジェクトに合わせたソリューションを設計し、競争力のある価格を提供します。
10分以内にご連絡します。

以下のフォームにご記入ください!

Photovoltaic (PV) Structural Design: A Comprehensive Guide to the End-to-End Mounting System Process

In a solar power project, the mounting system may seem like a “supporting actor,” but it is actually the backbone that supports the modules, ensures safety, and maximizes energy yield. For industry professionals, poor design leads to micro-cracks in modules and power loss; at worst, it causes structural collapse and catastrophic financial failure.

This guide breaks down the professional design workflow—from initial environmental assessment to structural calculation and final verification—to ensure your project is reliable, bankable, and built to last.


unnamed 4

I. Preliminary Preparation: Mastering Site Conditions to Prevent Design Deviations

Expert design begins with data, not drawings. The core logic of a mounting system is “site-specific adaptation.” We focus on three critical dimensions:

1. Scenario and Environmental Analysis

  • Project Type: Is it ground-mounted, rooftop (flat/pitched), floating PV, or BIPV? Each requires a fundamentally different logic for drainage, land clearing, or load distribution.
  • Environmental Loads: We collect high-precision data on:
    • Wind Load: Local basic wind pressure, gust coefficients, and topographic factors (coastal vs. mountainous).
    • Snow Load: Maximum snow depth and density, including freeze-thaw cycles.
    • Seismic Rating: Earthquake intensity parameters for structural resilience.
    • Corrosion Factors: Salt spray (coastal), high humidity, or sandstorms (desert) dictate material and coating selection.

2. Module Specifications and System Requirements

The bracket serves the module. We confirm dimensions, weight, and orientation (Portrait vs. Landscape). High-power modules (182mm/210mm) are heavier and have larger surface areas, requiring higher purlin strength and specific clamping zones.

3. Geological and Civil Surveys

For ground projects, we analyze soil bearing capacity and groundwater levels to choose between concrete strips, helical piles, or rammed posts. For rooftops, we audit the original structural drawings to calculate residual load capacity and ensure waterproofing integrity.


unnamed 1

II. Conceptual Design: Balancing Performance with Cost-Efficiency

Once the data is set, we move to the solution phase. Our goal is to maximize ROI by balancing safety with material economy.

  • Structural Selection: We choose between Fixed-Tilt (low maintenance, cost-effective) and Tracking Systems (10-20% yield increase). Material choice—Aluminum Alloy (lightweight, corrosion-resistant for roofs) or Steel (high strength, cost-effective for large-scale)—is optimized for the site.
  • Parameter Optimization: We use software simulation (e.g., PVSyst) to determine the optimal tilt angle for maximum irradiation, while calculating row spacing to eliminate inter-row shading during winter solstices.
  • Foundation Engineering: Selecting the “roots” of the system. Whether it’s a ballasted system for non-penetrative roof mounts or specialized piles for soft soil, the foundation is engineered for long-term stability.

III. Structural Calculation: Protecting the “Safety Bottom Line”

We don’t “guesstimate” safety. Our engineers use professional software (PKPM, SAP2000, ANSYS) to perform rigorous checks based on international standards (e.g., AS/NZS 1170, Eurocode, or GB standards).

  • Load Combination Analysis: We simulate the “worst-case scenarios” by combining dead loads (weight), live loads (maintenance), wind loads (uplift and pressure), and snow/seismic loads.
  • Component Stability: We verify the bending, shearing, and buckling strength of every post, purlin, and brace.
  • Connection Node Audits: Nodes are often the weakest links. We perform detailed checks on bolt shear, clamp tension, and anti-slip resistance to prevent local failures from cascading into a total collapse.

IV. Detailed Engineering & Technical Disclosure: Bringing Design to Life

A design is only as good as its execution. We provide:

  • Comprehensive Blueprints: Precise component dimensions, node details, and foundation layouts.
  • Technical Disclosure: We provide construction units with specific torque requirements for bolts, installation tolerances, and anti-corrosion coating procedures.
  • Detail Orientation: For example, specifying exact tightening torques ensures that joints don’t loosen over time due to vibration while avoiding damage to the structural members from over-tightening.

unnamed

V. Verification and Optimization: Closing the Quality Loop

Our commitment continues after the design is delivered:

  • On-site Inspection: We verify installation accuracy and coating thickness (using ultrasonic gauges) to ensure the physical build matches the digital twin.
  • Long-term Monitoring: For utility-scale projects, we monitor structural deformation under actual environmental stress to refine and optimize future iterations.

The Verdict: Design is the Art of Balance

In PV mounting systems, the goal isn’t just “strength”—it is the perfect equilibrium between safety, cost-efficiency, and ease of installation. By following a rigorous, closed-loop design process, we eliminate hidden risks and ensure your solar assets perform for their intended 25+ year lifespan.

愛を分かち合いましょう
テス
テス

太陽光発電業界の専門家として、高品質なソーラー架台の設計、製造、供給を専門としています。再生可能エネルギーへの深い情熱を持ち、最新の業界動向から技術的な専門知識まで、太陽光発電(PV)架台ソリューションに関する実用的な洞察と貴重な知識を共有することを目指しています。私の目標は、太陽光発電プロジェクトの成功におけるソーラー架台の重要な役割に焦点を当てた有益な記事を読者に提供することです。技術的なアドバイスだけでなく、現場での体験談や経験談も交えて、プロと愛好家の双方を刺激し、導いていきます。

新製品パンフレット

当社の応力解析の専門知識は、ソーラー架台ソリューションの最適な性能と費用対効果を保証します。 今すぐダウンロードするには、Eメールを入力してください。